Mettler Toledo SmartTouch 8461 Uživatelská příručka Strana 1

Procházejte online nebo si stáhněte Uživatelská příručka pro Tisk a skenování Mettler Toledo SmartTouch 8461. Mettler Toledo SmartTouch 8461 User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 68
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
UC-ST
SmartTouch
®
Scale/Printer
User’s Guide
64056467.R03
Zobrazit stránku 0
1 2 3 4 5 6 ... 67 68

Shrnutí obsahu

Strany 1 - Scale/Printer

UC-ST SmartTouch® Scale/Printer User’s Guide 64056467.R03

Strany 2

For your notes

Strany 3 - METTLER TOLEDO

This chapter covers • Label Installation CHAPTER 1 LOADING LABELS A label loading diagram can be found on the inside of the printer door for quick

Strany 4 - BUSINESS REPLY MAIL

Loading Labels 1-2 UC-ST User Guide Install the label roll on the supply spool and remove about 6 inches of labels from the liner. Slide the

Strany 5 - (Year of Declaration 2003)

Loading Labels Gently push in on the green knob to lock the liner into place, and then turn the roller clockwise to take

Strany 6 - WARNING

Loading Labels 1-4 UC-ST User Guide After installing the labels, select the label size as shown below. Refer to the UC-ST Service Manual for d

Strany 7 - Disposal

This chapter covers • Power Switch • Scale Operation • DB Editor Operation CHAPTER 2 OPERATION This chapter will explain the power switch, how to

Strany 8 - CONTENTS

Operation LEVELING THE SCALE The UC-ST scale must be level and installed on a stable counter. The level indicator is located behind the customer di

Strany 9

Operation QUICK START The operator display and keyboard is a touchscreen. You simply press the keys displayed on the screen. But, please only use yo

Strany 10 - For your notes

Operation Main Numeric Entry Screen Indicates scale is Zero Gross indicates no tare is taken. Net indicates weight is net (tar

Strany 11 - OADING LABELS

Operation Preset Mode Screen Selects Numeric PLU Entry Screen Accesses Unit Setup Mode or the Master Editor. Selects another Preset Pa

Strany 12 - 1-2 UC-ST User Guide

©Mettler-Toledo, Inc. 2009 No part of this manual may be reproduced or transmitted in any form or by any m

Strany 13 - UC-ST User Guide

Operation Print By-Weight PLU Service Mode To weigh one transaction of a single item, use Service Mode. Service Mode is normally the default on the

Strany 14 - 1-4 UC-ST User Guide

Operation Print By-Weight PLU Prepack Mode When weighing more than one package of a single item, use the Prepack Mode (see below #2). Prepack Mode r

Strany 15 - PERATION

Operation Print By-Count or Standard Pack Single Label To print a single label for by-count or standard pack without changing the quantity, follow

Strany 16 - LEVELING THE SCALE

Operation Batch Queue Mode Batch Queue Mode is used to print batches of labels. To print Nutrition Facts or Extra Text Labels, select the label form

Strany 17 - ENTER and ENTER/PRINT keys

Operation Zero the Scale If zero (0.00) is not displayed when the scale is at the Main Screen (without any items on the platter) check for obstruct

Strany 18 - Main Numeric Entry Screen

Operation CALLING PLU RECORDS PLU (Price Look Up) records are called (retrieved from file) two ways: Numeric Entry (Enter the PLU number on the keyb

Strany 19 - Preset Mode Screen

Operation PLU Edit Screen After a PLU is selected, the PLU Edit screen will display. This display will differ depending on the PLU types used. If

Strany 20 - 2-6 UC-ST User’s Guide

Operation By-Weight PLU Service Mode Call the PLU. If PREPACK is displayed on the EDIT screen, press that key to toggle to SERVICE. Place the item

Strany 21 - UC-ST User’s Guide

Operation Standard Pack PLU If the PLU is priced as a Standard Pack item, enter the quantity of labels desired (default is 1), then press PRINT to

Strany 22 - 2-8 UC-ST User’s Guide

Operation COOL – COUNTRY OF ORIGIN LABELING This section describes COOL operation if it is enabled set up properly on your scale. The COOL Text is n

Strany 23 - Batch Queue Mode

METTLER TOLEDO® Customer Feedback If you have a problem with one of our products or publications, or just a suggestion on how we can serve y

Strany 24 - 2-10 UC-ST User’s Guide

Operation The screen below shows the “Restricted Mode” COOL text screen. In this mode, the default COOL text assigned to the PLU will be highlighte

Strany 25 - CALLING PLU RECORDS

Operation You may be required to select or add a Tracking Number. The tracking number select and edit screens are shown below. The tracking number m

Strany 26 - PLU Edit Screen

Operation MANUAL OVERRIDES The operator can change PLU fields that are double-boxed in the PLU Edit screen. Instructions for editing the fields fol

Strany 27 - By-Weight PLU

Operation Shelf Life and Use-By Date Overrides The Numeric keyboard will appear. If allowed, touch the “Use By Date” area and enter the new number

Strany 28 - 2-14 UC-ST User’s Guide

Operation OPERATOR TOTALS Operator Totals allow totals to be recorded for up to 30 operators per department. Operators are defined by number and na

Strany 29

Operation MEMORY MODE When enabled, this feature allows the user to accumulate the items purchased by a customer. When the sale is complete, an item

Strany 30 - 2-16 UC-ST User’s Guide

Operation SUBTOTAL Screen and Options 1. CONTINUE to call up another item for the same customer and enter it into memory. 2. REMOVE ITE

Strany 31

Operation STANDALONE MODE DB EDITOR Your scale may be set up as a Standalone Scale that has an internal database of records. If you are in Standalo

Strany 32 - MANUAL OVERRIDES

Operation Edit The Edit functions allow editing the following records in the database: • PLU Records (see below for details) • Linked Records (se

Strany 33 - Extra Text Overrides

Operation Tare1/Ounces This field changes depending on the PLU type. For Price Per Pound, Price Per Half Pound, Price Per Quarter Pound, and Pounds

Strany 34 - 2-20 UC-ST User’s Guide

FOLD THIS FLAP FIRST BUSINESS REPLY MAILFIRST CLASS PERMIT NO. 414 COLUMBUS, OH POS

Strany 35 - EMORY MODE

Operation Action Code Enter the Action Code (1-50). An Action Code will perform specific functions when the PLU is called depending on the functio

Strany 36 - 2-22 UC-ST User’s Guide

Operation Sp. Price Type Select the type of discount, or press None for no Frequent Shopper Pricing. List Price - (similar to a Mfg. Suggested List

Strany 37 - TANDALONE MODE DB EDITOR

Operation Linked Records Select Linked Records to edit various linked records. Select the type of linked record, then enter the associated n

Strany 38 - 2-24 UC-ST User’s Guide

Operation Clear The Clear menu allows clearing the following items in the Standalone Database. • All Accumulators by Department • PLU Accumulators

Strany 39

Operation 2-30 UC-ST User’s Guide Operation 2-30 UC-ST User’s Guide For your notes

Strany 40 - 2-26 UC-ST User’s Guide

This chapter covers • Setup • Configuration CHAPTER 3 CONFIGURATION OPTIONS This chapter covers setup and configuration of features such as networ

Strany 41

Configuration Options Program Presets Preset Keys allow calling a PLU record with one touch of a programmed key. From the Unit Setup screen, touc

Strany 42 - 2-28 UC-ST User’s Guide

Configuration Options Touch EDIT, then the preset key to add or edit a preset. Touch the department box to select a new department. To c

Strany 43

Configuration Options SET PRESET TOUCH REACTION PRESET TOUCH REACTION configures how the preset keys react when touched. EDIT PLU When a prese

Strany 44 - 2-30 UC-ST User’s Guide

Configuration Options SETUP MARQUEE From the Unit Setup screen, touch SETUP MARQUEE to display the Marquee Setup screen. The messages shown on the M

Strany 45 - OPTIONS

Mettler-Toledo Inc. Columbus, Ohio Declaration of Conformance to SMA Standard Production Meets Type (Year of Declaration 2003) We the manufactu

Strany 46 - 3-2 UC-ST User’s Guide

Configuration Options CHANGE TIME AND DATE From the Unit Setup screen, touch CHANGE TIME/DATE to bring up the Time and Date screen. To make chang

Strany 47 - Configuration Options

Configuration Options NETWORK SETUP If the network is local, any number can be selected for the IP Address. An IP Address consists of a group of fou

Strany 48 - 3-4 UC-ST User’s Guide

Configuration Options You must first select the network boot type, Manual or Automatic. Automatic is the default. Automatic will use DHCP to auto

Strany 49 - ETUP MARQUEE

Configuration Options SERVER IP This may be displayed, but is not used in the standalone mode. SERVER NAME This may be displayed, but is not used in

Strany 50 - 3-6 UC-ST User’s Guide

Configuration Options 3-10 UC-ST User’s Guide For your notes

Strany 51 - ETWORK SETUP

CHAPTER 4 MAINTENANCE This chapter covers cleaning of the UC-ST. CLEANING • Disconnect power. WARNING DISCONNECT ALL POWER TO THIS UNIT BEFO

Strany 52 - 3-8 UC-ST User’s Guide

Maintenance 4-2 UC-ST User’s Guide PRINTER Clean the printhead anytime you notice the print quality has degraded using a cleaning pen or alcohol

Strany 53

CHAPTER 5 LABEL REQUIREMENTS The purpose of this chapter is to specify the requirements of thermal labels to be used in Mettler Toledo retail scale

Strany 54 - 3-10 UC-ST User’s Guide

Label Requirements Adhesive Permanent pressure sensitive – Nominal thickness 10 µ meter (0.0004 inch) Label must adhere to product with a surface

Strany 55 - AINTENANCE

Label Requirements FINISHED LABEL ROLL REQUIREMENTS Core and Method of Label Attachment The label stock must not be permanently attached to the card

Strany 56 - 4-2 UC-ST User’s Guide

PRECAUTIONS WARNING FOR CONTINUED PROTECTION AGAINST SHOCK HAZARD CONNECT TO PROPERLY GROUNDED OUTLET ONLY. DO NOT REMOVE THE GROUND PRONG. READ

Strany 57 - REQUIREMENTS

Label Requirements Winding The labels must be wound face out as shown in the figure below. The finished roll must be made free of paper dust and

Strany 58 - Label Stripping

Label Requirements Splicing Each roll may contain one splice on non-label side of liner using 0.002 inch maximum thickness tape as shown below. UC

Strany 59 - Slitting

Label Requirements FINISHED LABEL AND ROLL DIMENSIONAL REQUIREMENTS CORE ID: 1.56 INCH (40 MM) CORE WIDTH: 2.69 ± 0.03 (68.3 MM ± 0.8 MM

Strany 60 - 5-4 UC-ST User’s Guide

Label Requirements PREPRINTED LABELS To ensure trouble free operation of the printer gap sensor, and to achieve normal print head life, no pre print

Strany 61 - Splicing

Label Requirements SPECIAL SHAPED LABELS Labels with shapes other than rectangular will cause gap detection errors if the gap dimension in the ga

Strany 62 - 5-6 UC-ST User’s Guide

Label Requirements LABEL AND LINER OPTICAL DENSITY If liner paper transmits 2% of the light which is incident on it, the optical density is log10 (

Strany 63 - REPRINTED LABELS

Label Requirements 5-10 UC-ST User’s Guide For your notes

Strany 65 - LACK STRIPE OPTICAL DENSITY

14001Quality certification. Development, production, and auditing in accordance with ISO9001. Environmental management system in accordance with

Strany 66 - 5-10 UC-ST User’s Guide

Publication Revision History Part Number Date Revisions 64056467 Rev 01 5/06 System Management Setup, new Screens, DB Editor changes 64056467 R

Strany 67

CONTENTS CHAPTER 1 Loading Labels ...... 1-1 CHAPTER 2 Operation ...

Strany 68

CHAPTER 3 Configuration Options............... 3-1 Unit Setup ...........

Komentáře k této Příručce

Žádné komentáře